Crude Overhead Line

Our Latest Blog Posts
22
Mar

Crude Overhead Line

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview Customer installed new overhead lines connecting units. Lines located in un-accessible areas and wanted data on corrosion rates and inspection needs. Customer installed permanently installed UT sensors to monitor pipe intrados, extrados, top & bottom locations[/vc_column_text][/vc_column][/vc_row][vc_row full_width="stretch_row" css=".vc_custom_1490130489208{padding-top: 25px !important;padding-bottom: 25px !important;background-color: #fafafa !important;}"][vc_column][vc_column_text] Application Crude Overhead Line 300F-100F 12” Sch. 40 … all nominal wall thickness .4” +/- 12% [/vc_column_text][/vc_column][/vc_row][vc_row full_width="stretch_row"…

Read more →
22
Mar

Vacuum Fractionator

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview Customer built new unit to increase production. H2S line prone to corrosion at two different 90s before overhead line. Elected to use non-intrusive permanently installed UT sensors to monitor pipe intrados, extrados, top & bottom locations in lieu of installing a heat trace to maintain dew point.[/vc_column_text][/vc_column][/vc_row][vc_row full_width="stretch_row" css=".vc_custom_1490130489208{padding-top: 25px !important;padding-bottom: 25px !important;background-color: #fafafa !important;}"][vc_column][vc_column_text] Application Vacuum Fractionator ~300F 12” Sch. 40…

Read more →
22
Mar

Hydro-Fluoric (HF) Alky Unit Monitoring

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview Customer was sending NDT technicians to inspect the top of the HF Alky unit daily to monitor specific low spots to ensure wall loss did not exceed minimum required rate before outage planned in 6 mo. Now using system to correlate corrosion data to integrity operating windows (IOWs)[/vc_column_text][/vc_column][/vc_row][vc_row full_width="stretch_row" css=".vc_custom_1490130489208{padding-top: 25px !important;padding-bottom: 25px !important;background-color: #fafafa !important;}"][vc_column][vc_column_text] Application HF Alky Unit (HF Isostripper…

Read more →
22
Mar

Atmospheric Gas – Oil Line Monitoring

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview Customer wants to extend life to next turn-around and make sure that line is no longer corroding.[/vc_column_text][/vc_column][/vc_row][vc_row full_width="stretch_row" css=".vc_custom_1490130489208{padding-top: 25px !important;padding-bottom: 25px !important;background-color: #fafafa !important;}"][vc_column][vc_column_text] Application Atmospheric gas-oil, ~270C 3” Sch 40, subject to severe but uniform corrosion, most piping is < ½” nominal wall [/vc_column_text][/vc_column][/vc_row][vc_row full_width="stretch_row" css=".vc_custom_1490130495878{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Product Used smartPIMS HT Cellular w/ 4 HT probes temporarily…

Read more →
22
Mar

Pipeline Integrity: Storage/Injection

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview Due to PHMSA 49CFR191 & 49CRF192 more stringent regulation on transmission & distribution inspection & monitoring[/vc_column_text][/vc_column][/vc_row][vc_row full_width="stretch_row" css=".vc_custom_1490130489208{padding-top: 25px !important;padding-bottom: 25px !important;background-color: #fafafa !important;}"][vc_column][vc_column_text] Application Asset integrity post pigging/ILI examinations … <150F During Direct Assessment (DA), operator must make the decision to “bury & hope” or immediate fix/repair based on wall-thickness Operator elected to fix/repair either using a sleeve or new pipe…

Read more →
22
Mar

Pipeline Integrity – Area Monitoring

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview Operator performed ILI screening for first time since the pipeline had been constructed (7 years prior) and found a 3 feet section of pipe which saw >25% wall loss at 6:00 position. Operator cut out the pipe section and sent to lab for microbiology lab for evaluation. The individual welded in a new pipe section and installed matPIM where corrosion was previously…

Read more →
22
Mar

Pipeline New Construction

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview An operator found internal corrosion during an ILI run and decided the pitting required a segment of the pipe needed to be replaced. The location of the localized corrosion was unexpected and concerning with the severity of the pitting so the operator decided to monitor the same area on the new pipe where the previous failure occurred in order to gather periodic…

Read more →
22
Mar

Pipeline Corrosion Monitoring

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview Customer installed new pipeline to feed untreated water to their refinery instead of treated water which would save approximately $600,000,000 per month. The new pipeline needed to be monitored in the areas where the pipe was internally uncoated next to welded joints. Each of the 16 points were then environmentally sealed and buried.[/vc_column_text][/vc_column][/vc_row][vc_row full_width="stretch_row" css=".vc_custom_1490130489208{padding-top: 25px !important;padding-bottom: 25px !important;background-color: #fafafa !important;}"][vc_column][vc_column_text] Application…

Read more →
22
Mar

Pipeline Integrity – Gas Line

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview An ILI report showed a number of low spots at three separate locations along a 100 feet stretch of gas pipeline. When the previous ILI was performed 7 years prior, these low spots did not exist. The operator not only wanted data to tell if the corrosion was episodic or in nature or active but also did not want to fix/repair the…

Read more →
21
Mar

Pipeline Integrity – Liquid Line

[vc_row full_width="stretch_row" css=".vc_custom_1490129384251{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_column][vc_column_text] Overview Operator performed ILI using a smart pig to inspect a segment of their crude oil pipeline. The ILI report showed a number of pits which were not present the last time the ILI was completed. The operator wanted to know if the pits were episodic in nature or were growing (and if so, at what rate).[/vc_column_text][/vc_column][/vc_row][vc_row full_width="stretch_row" css=".vc_custom_1490130489208{padding-top: 25px !important;padding-bottom: 25px !important;background-color:…